The ACURA 810 air displacement pipette with two pre-calibrated volumes allows for sequential pipetting of 1 and 0.1 ml of the same liquid.
The metal nozzle allows you to adapt long straw tips for aspiration from narrow or deep reservoirs (e.g. Stomacher® bags).
This solution represents the ideal alternative to graduated glass pipettes for performing 1:10 dilutions in sequence in the bacteriological field.
Three year warranty.
- Two pre-calibrated fixed volumes;
no setting required - Quick and effortless activation;
maximum ergonomics - Protective filter for inter nozzle
exchangeable in PE - Jus tipTM system with adjustable ejector
of the tip * - Independent calibration of each volume
- Simplified maintenance, cleaning and disinfection
- Fully autoclavable 121 ° C / 250 ° F
Two pre-calibrated volumes |
 | No volume setting is required for pipetting from 1 mL and 0.1 mL. Both volumes are pre-calibrated at different stop positions along the same plunger. To increase flexibility in dilution operations, either or both volumes can be used. |
Optimized ergonomics |
 | Shape, lightness and ultra-smooth sliding of the piston are the key elements of the new Acura ® manual family. The precision pipette offers more than just a performance of results, in both research and routine applications. Exceptional convenience, comfort, safety and robustness: this is what your Acura ® pipette offers. |
Straw tip ejection device |
 | Positioned according to the best ergonomic criteria, the large cushioned ejector button guarantees a force-free activation. In addition to the comfort of the tip release, the rod height adjustment system, called Justip TM - controlled by efficient snap stops - allows you to choose from a wide range of tips to be applied on the nozzle. |
| |
Straw tips |
 | For Acura ® manual 810 dilution pipettes. Long tips (190 x 4 mm) allow collection of liquids with particles in Stomacher ® bags without causing blockages. Qualitips ® straw tips can be used directly in microbiological tests. Supplied sterile in resealable bags of 25 tips (Cat. No. 313.1100). |
Filters for pipette nozzles |
 | Increased protection against liquid filling or pipette contamination. Filters are interchangeable, non-sterile, non-autoclavable. |
Sterilization |
 | There is almost no maintenance required. Deep cleaning and sterilization are achieved by autoclaving the fully assembled instrument (121 ° C, 20 minutes). |
AQ Certificate |
 | Each micropipette bears its own serial number and undergoes a rigorous functional check, attested by an individual QA certificate. |
Dilution 1: 10 |
 | Pipetting operation 1. Push the plunger fully in, then slowly release it to draw 1.1ml 2. Push the plunger to the first stop to dispense 1 mL into the Petri dish 3. Push the plunger to the second stop to dispense the remaining 0.1 mL into the next Petri dish |